+86-755-33168386  sales@china-gauges.com

Technological innovation

IPX7 and IPX8 Immersion: Depth, Duration, Buoyancy and Seal Checks

IPX7 and IPX8 Immersion: Depth, Duration, Buoyancy and Seal Checks

Writer: admin Time:2026-11-15 09:30 Browse:℃

Immersion testing looks like the easiest ingress test: put the enclosure underwater for a while and see if it survives. In practice it has its own pitfalls, mostly around getting the depth right, keeping the sample down, and remembering that a seal behaves differently under pressure than it does on the bench. IPX7 and IPX8 are both immersion, but IPX8 is defined by the manufacturer for a deeper, longer condition than the standard IPX7 minimum.

Depth and duration

IPX7 is specified as immersion to a depth of at least 1 m, typically 1 m plus the sample height, for 30 minutes. The depth is measured from the top of the sample to the water surface, not from the bottom of the tank. IPX8 is whatever the manufacturer declares, usually deeper and often longer, and the declaration is what the certificate must quote. A test run at "about a metre" with no recorded depth is not a defined severity.

RatingDepthDuration
IPX7≥1 m above top of sample30 min
IPX8Manufacturer-declared, deeperManufacturer-declared, longer

The buoyancy problem

Many enclosures float, and a floating sample is not at the specified depth and may not be fully submerged at the top. Weigh it down with a non-damaging harness, or suspend it, so the whole enclosure sits at the required depth for the whole duration. A sample bobbing at the surface has not been immersed to specification, and the result is meaningless.

Seals under pressure

A gasket that seals fine in air can relax or deflect under water pressure, especially on a large, thin panel or a poorly retained seal. For IPX8, the higher pressure makes this worse, not better. Check that covers stay seated, that a drain or vent that is normally closed really is closed for the test, and that no fastener was left loose. A seal that holds at 1 m may not hold at 3 m.

  • Record the actual depth from the top of the sample.
  • Keep the sample fully submerged with a harness, not by hand.
  • Set cable glands and covers exactly as in service.
  • For IPX8, test to the declared depth, not the IPX7 minimum.

Pre and post functional check

Run a functional check before immersion and again after, with the enclosure opened promptly and photographed before wiping. The acceptance is that water did not reach live parts or insulation in a way that affects operation or safety. A few drops in a low, drained corner may be acceptable; water on a terminal block or a PCB is not. If the sample contains air that compressed under depth, let it equalise before judging, because a pressure-related bubble is not the same as ingress through a failed seal.