IEC 60529 keeps repeating one instruction for the water tests: the enclosure is tested in its position of normal use. It sounds like housekeeping. It is actually the load-bearing clause, because an enclosure is not a box with a fixed water path. Rotate it 90 degrees and a drainage channel becomes a reservoir.
Everything else in the setup can be perfect and still give the wrong answer if the sample is lying on its back when it was designed to stand upright.
The most common reason to prop a sample is to reach a cable or to keep it out of standing water. Both are reasonable workshop instincts and both change the test. A 20 mm block under one corner tilts a 300 mm wide enclosure by nearly 4 degrees, which is enough to move water from a drained recess into a connector cavity.
If the enclosure has feet, use them. If it has a mounting flange, mount it. If it has neither, note in the record that it was tested free-standing and on which face.
Cable glands, blanking plugs, gaskets, and the terminal cover are all part of the ingress path. Removing them makes the test easier and the result meaningless. The rule is simple: test what ships. If a gland is optional, test with it fitted and note the variant.
| Part | Test with it? | Why |
|---|---|---|
| Cable gland as shipped | Yes | It is the seal being certified |
| Terminal cover | Yes | It defines the cavity that fills |
| Drain plug | Yes, in place | Removing it creates a path that does not exist in service |
| Optional accessory not fitted | No, but note it | Certify the configuration you tested |
| Shipping cap over a connector | No | It is removed before use, so it is not part of the enclosure |
A gland that points down sheds water. The same gland pointing up collects it in the cap and works it past the seal by capillary action over an hour. Vendors who ship the same enclosure with a top entry and a bottom entry need two results, not one.
Tie the cable in the orientation the customer will use, with a drip loop if the installation drawing calls for one. The drip loop is not decoration: it is the difference between water running away from the gland and water running into it.
For the oscillating tube, the sample sits at the centre of the arc, with the tube radius chosen so the spray reaches the whole surface. For the spray nozzle tests, the distance from the nozzle to the nearest surface is held at 2.5 m to 3 m, and the sample is rotated or traversed so every face is exposed. A sample clamped against the wall of the chamber has one face that never sees a jet.
Fixture contact matters more than most labs admit. A clamp face of 40 mm by 60 mm covers 2,400 mm². Across a 400 mm by 300 mm enclosure that is 2 % of one face and nobody notices. Put the same clamp across a 150 mm gland plate and it shadows a third of the surface that is supposed to be sprayed.
Keep fixture contact under 10 % of any single face, and note on the sketch where the clamps sit. If a face needs a clamp to hold the sample upright, that face is not being tested properly and the record should say so.
Record four things and the mounting problem disappears from the argument list: the face orientation, the parts fitted, the distance to the nozzle, and whether the sample was conditioned at room temperature first.