+86-755-33168386  sales@china-gauges.com

Technological innovation

Pressure Decay as an IPX7 Screen: What It Finds and What It Cannot

Pressure Decay as an IPX7 Screen: What It Finds and What It Cannot

Writer: admin Time:2026-11-22 09:30Browse:℃

Immersion testing has three problems: it is slow, it leaves the sample wet, and it is destructive if water gets in. Pressure decay testing avoids all three, which is why it is often proposed as a substitute. It is not a substitute. It is a screen, and a good one, provided the limits are understood.

What pressure decay measures

A sealed enclosure is pressurised (or evacuated) to a defined differential, isolated from the source, and the pressure is watched for a fixed period. A drop means air is leaving; the rate of drop is related to the size of the leak.

The measurement is sensitive. Under favourable conditions, a decay test can detect a leak of a few cubic centimetres per minute, which corresponds to a pinhole far smaller than anything a visual inspection would find.

The result is expressed as a pressure change over time, or converted to an equivalent leak rate. What it does not express is how much water would enter during a 30-minute immersion.

MethodDetectsMisses
pressure decaythrough-leaks in a sealed volumeseam creep under hydrostatic head
immersionactual water entry over timenothing, but is slow and wet
air pressure decay on an unsealed productnothing usefuleverything

The assumption nobody states

Pressure decay works on a closed volume. Most products that need IPX7 are not closed volumes: they have a cable entry with a gland that seals only under compression, a membrane vent that passes air by design, or a gasket that seals water but not a 0.3 bar air differential.

A vent membrane is the clearest example. It is designed to equalise pressure slowly, which means a pressure decay test on a vented enclosure will show a decay that has nothing to do with water ingress. Testing such a product with decay requires either blocking the vent (which changes the product) or accepting that the method does not apply.

Where it earns its place: as a production screen

Used on a defined population of identical parts, with a limit established by correlation against immersion results, pressure decay is excellent. It runs in seconds, it is dry, and it catches the assembly errors that matter most — a missing gasket, a gland not tightened, a connector seated halfway.

The correlation step is what makes it valid. Test 30 samples by immersion, record which leak, then run the same 30 by decay and find the threshold that separates them. That threshold is specific to the product and the fixture, and it has to be re-established whenever either changes.

What to write in the report

A decay test report should state: the differential pressure, the stabilisation time before measurement, the measurement period, the equivalent leak rate limit, and the correlation basis for that limit. Without the last item, the test is a number without a meaning.

And it should state what the test is not. A decay pass is evidence that the enclosure is sealed against air at the test differential. It is not evidence that the product meets IPX7; that still requires immersion, at 1 m, for 30 minutes, on a sample that has not been modified for the test.

The honest framing: pressure decay tells you whether to bother immersing. Immersion tells you whether the product passes.

PREVIOUS:EN 60529 Testing No Next

CONTACT US

Contact: Eason Wang

Email: sales@china-gauges.com

Tel: +86-755-33168386

Address: 1F Junfeng Building, Gongle, Xixiang, Baoan District, Shenzhen, Guangdong, China