IPX3 and IPX4 both describe protection against spraying water, and both can be tested two ways: with an oscillating tube that sweeps water over the sample, or with a hand-held spray nozzle directed at it. The two methods are permitted by the standard and they do not produce identical results.
The oscillating tube is a semicircular pipe with a row of holes, mounted so it rocks through a defined arc over the sample. Water arrives from many directions in a repeating sweep, at a flow rate set by the tube radius and hole spacing.
The spray nozzle is a hand-held device with a baffle, held at a defined distance and moved over the sample surface. Water arrives from one direction at a time, at a flow rate set by the nozzle, and the operator decides where it goes.
The tube is reproducible and covers the whole sample; the nozzle reaches places the tube cannot, and depends on the operator.
| Aspect | Oscillating tube | Spray nozzle |
|---|---|---|
| coverage | uniform over the arc | wherever the operator aims |
| reproducibility | high | operator dependent |
| large samples | needs a big tube, may not fit | handles any size |
The tube delivers water from above and the sides in a gentle sweep. Water runs down surfaces and collects at the lowest points. A product with a horizontal seam near the bottom is stressed by pooling, not by impact.
The nozzle delivers a directed stream with more momentum. It stresses the same seam from the side, driving water into the gap rather than letting it run past. A gasket that sheds running water can fail under a directed stream at the same flow rate.
The reverse also happens. A product with a deep recess that the tube cannot reach — because the tube arc does not align with the opening — may pass the tube test and fail when an operator directs the nozzle into the recess.
The product standard specifies the method, and where it allows either, the choice should be recorded. Mixing methods between the type test and a re-test makes the two results incomparable.
A common practical problem: the type test used the tube because the lab had one, and the customer's incoming inspection uses a nozzle because it is portable. The two disagree, and neither is wrong.
The tube radius is chosen so the sample fits inside the arc at the specified distance. A tube that is too small puts the sample too close and delivers more water per unit area; one that is too large puts it too far and delivers less.
The flow rate is set by the tube, not adjusted to suit the sample. If the sample is large enough that the specified flow cannot wet it within the test duration, the standard provides for a longer duration, not a higher flow.
The tube must oscillate through the specified arc at the specified rate. A slower sweep delivers more water per position; a faster one delivers less.
Distance and angle are specified, and both change the result. Closer means more impact pressure; a steeper angle means more water driven into seams.
The duration is specified per square metre of surface, which means the operator has to actually cover the surface at the specified rate. A nozzle waved quickly over the whole product has not delivered the specified exposure.
Method (tube or nozzle), tube radius or nozzle type, flow rate, distance, duration, and the orientation of the sample. Without the method, a pass is not reproducible — and an IP rating claimed without a stated method is a claim that cannot be checked.
For products tested both ways, record both results. A product that passes the tube and fails the nozzle has a real weakness at a specific location, and that location is worth knowing before a customer finds it.
Contact: Eason Wang
Email: sales@china-gauges.com
Tel: +86-755-33168386