The dust test has two levels, and the difference between them is not the quantity of dust. IP5X exposes the sample to circulating dust. IP6X does the same and adds one thing: it maintains a vacuum inside the enclosure, so dust is drawn toward any path that leads in.
In IP5X, dust enters an enclosure by diffusion and by whatever air movement the enclosure itself generates. A narrow path with no pressure difference admits very little.
In IP6X, the vacuum creates a pressure difference across every path. Air flows in, and dust travels with it. A path that admitted nothing under diffusion admits dust readily under flow.
That is why IP6X is a different test rather than a stricter IP5X: it changes the transport mechanism, not just the amount.
| Aspect | IP5X | IP6X |
|---|---|---|
| transport | diffusion | flow driven by pressure |
| criterion | no harmful quantity | no dust at all |
| typical failure | dust settles inside | dust traces along a path |
The standard specifies a vacuum, commonly expressed as a pressure difference in kilopascals or as a flow rate maintained through the enclosure. The value matters: too little and the test approaches IP5X, too much and the enclosure itself may be damaged or the sample may be drawn against the chamber wall.
A vacuum that cannot be maintained is the more common problem. If the enclosure leaks badly, the pump cannot hold the differential, and the test runs at a lower severity than specified without any indication on the equipment.
That is why the standard requires the vacuum to be monitored, not just applied. A test report that states the vacuum setpoint but not the maintained value has recorded an intention rather than a condition.
Three patterns appear repeatedly:
A gasket that seals under compression but not under differential. A soft gasket compressed between two surfaces seals against diffusion. Under vacuum, the pressure difference can lift the gasket edge, and dust follows the leak path.
A fastener boss with a blind hole. The hole does not penetrate, so there is no path for diffusion. But if the boss cracks at its base — a common moulding defect — the vacuum finds it.
A cable gland that seals the cable but not the entry. The gland grips the cable correctly, but its thread into the enclosure is not sealed. Under vacuum, air and dust enter along the thread.
The sample should be tested as it would be installed: cable entries fitted or plugged as in service, covers in place, and any temporary shipping seals removed. A sample tested with its cable entries open is a different product.
If the enclosure has a pressure-equalisation membrane, the vacuum will draw air through it. That is correct — the membrane is part of the product — but it means the test is measuring the membrane as much as the housing, and the result should be interpreted that way.
IP6X is judged by opening the enclosure and looking for dust. The judgement is qualitative and disputed more often than any other IP result, because "no dust" and "a trace" are opinions unless the criterion is defined.
Two practices reduce the dispute: photograph the interior before touching anything, and note the location of any dust rather than only its presence. Dust concentrated along a seam identifies the path; dust distributed evenly suggests it entered through many paths or was present before the test.
Powder type and mass, chamber volume, vacuum value maintained, duration, sample configuration, and inspection result with photographs.
The vacuum value is the field most often missing, and it is the one that distinguishes an IP6X test from a thorough IP5X test.