Writer: admin Time:2026-11-27 09:30Browse:℃
IPX7 is the immersion rating, and it is the one most often misunderstood because the numbers look simple: one metre, thirty minutes. The complication is what the metre is measured from, and what happens after the test.
IPX7 specifies immersion to a depth of 1 m for 30 minutes, measured from the lowest point of the enclosure to the water surface. Some standards allow the sample to be immersed in a pressure vessel to an equivalent pressure instead.
The reference point matters. A metre measured from the top of the product is a different test from a metre measured from the bottom, and on a tall product the difference is the whole test.
| Parameter | Value | If changed |
|---|---|---|
| depth | 1 m from lowest point | pressure changes about 0.1 bar per metre |
| duration | 30 min | ingress accumulates, short tests miss it |
| temperature | sample and water differ | thermal effect drives ingress |
A warm sample immersed in cool water cools down. The air inside contracts, creating a partial vacuum that draws water in through any path.
The standard specifies a temperature difference between sample and water, commonly with the sample warmer by a defined amount. Without that difference the test can pass products that fail in service, where a warm device is dropped into cold water.
Some standards remove the difference entirely and test at ambient. Those products are rated for immersion at ambient only, and the marking should say so.
The criterion is not that no water enters. It is that no water reaches a harmful location. A product with a sealed electronics compartment and a vented battery bay can pass with water in the bay.
That distinction is what makes post-test inspection the real test. Opening the product and finding water does not automatically mean failure; finding water on a live conductor does.
Immersing a sample in a pressure vessel to an equivalent pressure is accepted by many standards and is faster for large products. The equivalence is real for static pressure but not for the thermal effect: in a vessel the sample and the water are usually at the same temperature, so the cooling-driven ingress does not occur.
A product that passes in a vessel may fail in a tank. If the rating is meant to represent a real immersion event, the tank is the more faithful test.
Gland and grommet interfaces. The seal grips the cable correctly but the interface between seal and housing is not sealed. Static water pressure finds the interface.
Seams under a label. A label covering a seam looks like a seal. It is not, and water passes under it by capillary action.
Fastener inserts. A threaded insert in a plastic wall provides a path along the thread unless it is sealed or blind.
Membrane vents. A pressure-equalisation membrane passes air and blocks water at low pressure. At 1 m of head it may pass water in the reverse direction if the membrane is not rated for it.
Dry the exterior, then open immediately and inspect. Photograph before drying. Water evaporates from a warm product within minutes, and a delayed inspection turns a leak into a clean interior.
Check the low points first. Water collects at the lowest internal surface, which is where it will corrode a connection months later.
Depth and the reference point used, duration, sample and water temperature, whether a tank or a vessel was used, and the inspection result with photographs.
The reference point is the field most often missing and the one that makes two IPX7 results incomparable. A tall cabinet tested to 1 m from its top has been tested to several metres from its base, or the reverse, depending on which end the tester chose.
Contact: Eason Wang
Email: sales@china-gauges.com
Tel: +86-755-33168386
Address: 1F Junfeng Building, Gongle, Xixiang, Baoan District, Shenzhen, Guangdong, China