Writer: admin Time:2026-11-28 09:30Browse:℃
A dust test looks like the simplest test in the IP series: put the sample in a box, add dust, wait. The difficulty is that the dust is specified — its quantity, its particle size and its behaviour in the chamber all affect the result, and a chamber that is under-filled still produces a report.
The test uses talc powder, not sand and not workshop dust. The quantity is defined relative to the chamber volume, commonly 2 kg per cubic metre, and the test duration is 8 hours for both IP5X and IP6X.
The powder is specified by particle size: fine enough to behave as an aerosol and to enter the same paths that real dust enters. Sand is used for the sand tests, which are a different thing entirely.
| Parameter | Value | Effect if wrong |
|---|---|---|
| powder | talc, defined fineness | sand abrades instead of penetrating |
| quantity | 2 kg per cubic metre | thin cloud, fewer particles reach the paths |
| duration | 8 hours | short test under-reports accumulation |
| vacuum, IP6X | up to 2 kPa depression | no flow, so no dust drawn in |
The test is not a static exposure. The powder is kept airborne by circulation, and the concentration in the air is what drives deposition on surfaces and entry through gaps.
A chamber with too little powder has a thin cloud. The sample is coated, so it looks tested, but the number of particles that reach a narrow path is a fraction of what the specification intends. The product passes, and the test has measured a milder condition.
The reverse is also a problem: too much powder can clog the circulation and settle rather than circulate, which changes the distribution rather than increasing it.
IP6X adds a vacuum inside the enclosure, maintained at up to 2 kPa below ambient, so that air flows inward through any path and carries dust with it.
The vacuum must be maintained, not just applied. A leaky enclosure cannot hold the depression, and the test then runs at a lower differential while the gauge on the panel shows the setpoint.
The air has to come from somewhere. If the enclosure is sealed to the point that no air can enter, the vacuum cannot develop, and the test becomes an IP5X with a pump attached.
The standard resolves this by allowing a defined air flow through the enclosure instead of a pressure differential, and the flow rate is the parameter to record when that method is used.
Between two mouldings with a tongue-and-groove joint. The joint looks like a labyrinth; the powder behaves like a gas and follows it.
Around cable entries. A gland that seals the cable but not its own thread into the housing leaves an annular path.
Through fastener holes into a blind boss. No path in a good moulding, but a short shot or a weld line at the boss base opens one.
Through a vent membrane. The membrane passes air by design; whether it passes powder depends on the pore size, and it is part of the product being tested.
IP5X allows dust to enter but not in a quantity that interferes with operation or safety. IP6X allows no dust at all. Both are judged by opening the enclosure.
The judgement is qualitative and is the most disputed part of the test. Three practices reduce argument: photograph the interior before touching anything; note where the dust is, not only how much; and state the acceptance criterion in the report in the words of the standard clause being applied.
A report that says "some dust inside" has recorded an observation and deferred the decision to whoever reads it next.
The sample is tested as installed: covers fitted, cable entries as in service, temporary shipping seals removed. A sample tested with open entries is a different product.
If the product has a pressure-equalisation membrane, the vacuum draws air through it, which is correct — but it means the membrane is being tested, and a membrane that passes powder is a finding about the membrane, not about the housing.
Powder type and mass, chamber volume, duration, the vacuum or flow maintained, sample configuration and the inspection result with photographs.
The maintained vacuum is the field most often missing, and it is the one that distinguishes an IP6X test from a thorough IP5X test.
Contact: Eason Wang
Email: sales@china-gauges.com
Tel: +86-755-33168386
Address: 1F Junfeng Building, Gongle, Xixiang, Baoan District, Shenzhen, Guangdong, China